F643故障:Positive Travel Limit Switch Detected檢測(cè)到正行程限位開(kāi)關(guān)
The positive travel limit switch has been actuated. The axis has been stopped with the error reaction "set velocity command value to zero". Bit 2 of P-0-0090, Travel limit parameter has been set to "Exceeding the travel limit is an error", or a drive control command has been started while the axis limit value is exceeded (e.g. drive-controlled homing).正向行程限位開(kāi)關(guān)已啟動(dòng)。軸已停止,錯(cuò)誤反應(yīng)為“將速度命令值設(shè)置為零”。P-0-0090的第2位,行程限制參數(shù)已設(shè)置為“超過(guò)行程限制是一個(gè)錯(cuò)誤”,或者在超過(guò)軸限制值時(shí)啟動(dòng)了驅(qū)動(dòng)控制命令(例如驅(qū)動(dòng)控制復(fù)位)。
Cause:原因:
The positive travel limit switch has been actuated.
正向行程限位開(kāi)關(guān)已啟動(dòng)。
Remedial action:解決方法:
1. Reset the error
2. Activate the power supply
3. Move the axis into the permissible working range
1.重置錯(cuò)誤
2.激活電源
3.將軸移動(dòng)到允許的工作范圍內(nèi)